Skip to content

📦 Release Notes - 1.4.0

🛠️ Bug Fixes

  • [CPT iField] The Start or Complete Dissipation button doesn't send the command when pressed.
  • [CPT iField] Data is saved on DB after having problems with API.
  • [CPT iFIeld] The Reset Alarm action is inverted when the CPT Length is reached as soon the Data Acquisition screen is displayed.
  • [CPT iField] The graph shows a line on 0 depth after a dissipation test is added.
  • [CPT iField] The Settings are not loaded when the application is opened
  • [CPT iField] Disconnection toast message on RCC connection loss is displayed when in Vessel mode
  • [CPT HMI] The Base X and Y are not displaying the values when a test is started for the first time after the CPT is powered on.
  • [CPT HMI] The Rods are not sync with the real CPT rods.
  • [CPT HMI] HMI sporadically is not receiving topics when the Gateways are open before the application
  • [Real Operation] Unreal iField app crash and closes when entering the graphs screen after 2 hours in the zeros screen.
  • [iField API] The API disconnects when a not completed test is called on the endpoint oi/export/cpt
  • [DDS Tools] The command Async push is not stopping on the set depth.

✨ New Features & Improvements

  • [CPT iField] Update to latest ICC API (Jan 2026).
  • [CPT iField] Show loading when waiting for Zeroes
  • [CPT iField] View Dissipation Elapsed Time
  • [CPT iField] Reorder Test List
  • [CPT HMI] 3D Twister - Report When Clamps are Closed.
  • Optimize Topic Messaging and Prioritization.
  • Review Log Strategy for Gateways